Hardware & Software Requirements
This document is provided as a guideline regarding hardware configurations,
operating system and operating system patches recommended for the use with
CATIA Version 5 Release 17.
- Important Notice on AIX 5.2 Support
Version 5 Release 17 is the last release to support AIX 5.2.
Because end of support (EOS) for AIX V5.2 is September 1, 2007,
customers installing CATIA V5.17 are encouraged to migrate to AIX V5.3.
- Important Notice on Solaris 8 Support
Version 5 Release 17 will be the last release to support SUN
Solaris 8, customers currently running on Solaris 8 are encouraged to
migrate to Solaris 10
All Platforms
Recommended Memory
- 256 MB of RAM is the minimum recommended amount of memory for all
applications. 512 MB of RAM is recommended for ENOVIA DMU applications on large
assemblies, and for the Digitized Shape Editor 2 product. Requirements may be
greater when large amount of data are used.
Windows 2000 / Windows XP
Operating System
- Windows 2000 Professional with Service Pack 4, or higher is required, or
Windows XP Professional SP1 or SP2, with following components:
- Windows 2000, and Windows XP deliver an implementation of OpenGL
libraries. Dassault Systemes will provide recommendations related to driver levels
based on certified configurations at URL:
http://www.3ds.com/implementation/technology/windows/certified-workstations-list/. These drivers may offer
a CATIA Version 5 application setting (see Control Panel, Display
Properties tabs), which should be selected when available, as they may
contain application specific features.
- Localized version of the operating system may be required when selected
installation locale differs from Latin1
- Note : Version 5 Release 17 will be the last release to support
Windows 2000 Professional Edition
Certified and Derived Configurations
Please follow the link to the dedicated
page of the program directory.
Windows 64-bit
Operating System
- Windows XP Professional x64 Edition, with following components:
- Windows XP Professional x64 Edition delivers an implementation of
OpenGL libraries. Dassault Systemes will provide recommendations related to
driver levels based on certified configurations at URL:
http://www.3ds.com/implementation/technology/windows/certified-workstations-list/.
These drivers may offer a CATIA Version 5 application setting (see Control
Panel, Display Properties tabs), which should be selected when available,
as they may contain application specific features.
32-bit CATIA V5
- Although those Version 5 products are 32-bit applications, they will be
able to allocate up to 4GB of Memory when running on this operating system.
- KB903648 : When using macro and VBScript features,
V5 may crash when accessing more than 2GB of address space, a Microsoft
patch is correcting this problem , see Microsoft Article : KB903648
http://support.microsoft.com/default.aspx?scid=kb;en-us;903648.
- KB911021 : required for applications allowing more
than 2GB of address space . please contact your Microsoft support
representative.
64-bit CATIA V5
- No required patches
-
Note : For a 64-bit
process, memory consumption is completely different than for a 32-bit
process. In this conditions, it is not pertinent to compare the
« Virtual Bytes » counter of Perfmon between 32-bit process and 64-bit
process. Although this counter is important to track for a 32-bit process
because the global address space is limited to 4 GB including reserved
virtual memory, for 64-bit process, virtual address space can reach 8 TB.
-
Known issues : When
Japanese locales are used, console output will be corrupted at first
Japanese character display, the "cout << " does not print any character
after. This is a Microsoft CRT 8.0 bug and should be fixed by Microsoft.
32 and 64-bit CATIA V5 Certified configurations
Please follow the link to the dedicated
page of the program directory.
IBM AIX
Operating System
- AIX 5.2 Maintenance Level 07 (using 64-bit kernel) with following
components:
- XL C/C++ Enterprise Edition V7.0.0 Run-time Environment :
- XL 7 May 2005 PTF R/T (xlC.aix50.rte at level 7.0.0.6) ,
delivered trough APAR IY71976
- XL Fortran Enterprise Edition V9.1.0 for AIX Run-Time
- AIX 5.3 Maintenance Level 03 (using 64-bit kernel) with
following components:
- XL C/C++ Enterprise Edition V7.0.0 Run-time Environment :
- XL 7 May 2005 PTF R/T (xlC.aix50.rte at level 7.0.0.6) ,
delivered trough APAR IY71976
- XL Fortran Enterprise Edition V9.1.0 for AIX Run-Time
- IBM eServer P5 Server Support and IBM IntelliStation POWER 285
support requires AIX 5.3 ML03, with the above recommendations for
R17.
- Note : AIX 5.3 ML03 is supported on Power 4 and Power 5 based
system only.
- IBM IntelliStation POWER 285
support requires AIX 5.3 ML03, with the above recommendations for R17.
- Note :
- Version 5 Release 15 is the last release to support AIX 5.1
- Version 5 Release 17 will be the last release to support AIX 5.2
List of configurations certified with CATIA Version 5 is available at
http://www.3ds.com/implementation/technology/unix/unix-based-workstations/
HP-UX
Operating System
- Support of C8000 workstation with ATI Fire GL
X3-256 requires HPUX 11i (or 11.11) v1.0 with following bundles and
patches:
- HP-UX 11i TCOE June 2004 (Core OS)
- GOLDAPPS11i Gold Applications Patches for HP-UX 11i v1, June
2004
- GOLDBASE11i Gold Base Patches for HP-UX 11i v1, June 2004
- HWEnable11i Hardware Enablement Patches for HP-UX 11i v1, June
2004
- PHSS_30968 ld(1) and linker tools cumulative patch
- PHSS_31270 3D Common Run (PA2.0 only)
- PHSS_31271 PEX 5.1/Starbase/Hardcopy Run (PA2.0 only)
- PHSS_31274 Starbase/Hardware Dev (PA2.0 only)
- PHSS_31275 OpenGL 1.1 Dev (PA2.0 only)
- PHSS_31276 OpenGL 1.1 Run (PA2.0 only)
- PHSS_31281 Xserver cumulative patch
- PHSS_32185 C8000 PDC 2.12, BMC 2,32 Firmware patch
- PHCO_33360 libc cumulative patch
- PHSS_28880 HP aC++ -AA runtime libraries (aCC
A.03.50)
- PHKL_33258 VxFS cumulative patch; ml_flag
race
- Support of Fire GL X1 / T2/ X3-256 requires the following
customization :
- HP 11iv1 (11.11) December 2004 support requires:
- HP-UX Technical Computing OE Component December 2004
- Hardware Enablement Patches for HP-UX 11i v1, December 2004
- Gold Applications Patches for HP-UX 11i v1, December 2004
- Gold Base Patches for HP-UX 11i v1, December 2004
- With following patches applied :
- PHCO_31923 : libc cumulative header file patch
- PHCO_33360 : libc cumulative patch
- PHKL_31918 : fsadm;ACL;locking order;8K mount;readdir
- PHNE_32477 : ONC/NFS General Release/Performance Patch
- PHSS_29483 : HP aC++ Compiler (A.03.52)
- PHSS_31271 : PEX 5.1/Starbase/Hardcopy Run (PA2.0 only)
- PHSS_31274 : Starbase/Hardcopy Dev (PA2.0 only)
- PHSS_31275 : OpenGL 1.1 Dev (PA2.0 only)
- PHSS_32573 : HP aC++ -AA runtime libraries (aCC A.03.61)
- PHSS_32928 : 3D Common Run (PA2.0 only)
- PHSS_32934 : OpenGL 1.1 Run (PA2.0 only)
- PHSS_32939 : Xserver cumulative patch
- PHSS_33033 : ld(1) and linker tools cumulative patch
List of configurations certified with CATIA Version 5 is available at
http://www.3ds.com/implementation/technology/unix/unix-based-workstations/
SGI IRIX
Operating System
- IRIX 6.5.15m (C, C++ and Fortran runtime environments, at level 7.3.1,
are delivered with the operating system as well as OpenGL runtime
environment) plus following recommended patches :
- patch 4848 Poor network performance with ef interface on machines with
fast cpus
- patch 4815 libexc Update
- VPro graphics adapter requires following patch:
- patch 4674 VPro graphics limited-release bug fixes for Irix 6.5.15m
and Irix 6.5.15f
- In addition, support of Fuel Visual Workstations requires following
patch :
- patch 4695 IP35 6.5.15m PROM/kernel rollup/R14KA support
List of configurations certified with CATIA Version 5 is available at
http://www.3ds.com/implementation/technology/unix/unix-based-workstations/.
SUN Solaris
Operating System
- Solaris 8 HW 05/03 minimum (includes C and C++ runtime environments;
Fortran runtime environment is delivered with CATIA V5), with OpenGL 1.2.3
with following recommended packages and patches.
- Recommended packages
- SUNWlibC SPARCompilers Bundled libC
- SUNWglrt OpenGL for Solaris Runtime Libraries
- SUNWbtool CCS tools bundled with SunOS
- SUNWxwoft X Window system optional fonts 6.4.1
- Solaris 8 HW 05/03 with following patches :
- 108652-83 Xsun
- 112628-29 OpenGL 1.2.3
- XVR-600 graphics adapter requires OpenGL 1.3
minimum with following recommended patches (XVR-1200 is also supported with
this configuration) :
- 114554-12 XVR1200 Graphics Accelerator patch
- 113886-22 OpenGL 1.3 patch
- 108940-68 Motif2.1
- Sun Blade 1500+ (1.5GHz) requires Solaris 8 02/04 and OpenGL 1.3 with following
patches :
- 114554-12 XVR1200 Graphics Accelerator patch
- 113886-26 OpenGL 1.3 patch
- 108652-83 Xsun
- 108940-68 Motif2.1
Notes :
- Elite3D M3 graphic adapter is not supported on Ultra10 except on
Ultra10/440 MHz.
- Solaris 10 SPARC Operating System Release 03/05 is supported on Sun
Blade 1500, 2500 or 1500+, with XVR1200 or XVR600 graphic adapters.
- Known issues :
- On Solaris 8 and 10, the Ctrl Key does not invoke the appropriate
actions. This is a SUN Motif 2.1 problem and will be fixed by a SUN Motif
2.1 patch.
- On Solaris 10, when using Scrollbar for Multi-lists, users may
encounters coredumps . This is a SUN Motif 2.1 problem and will be fixed by
a SUN Motif 2.1 patch
List of configurations certified with CATIA Version 5 is available at